Abstract
To collect beam loss information from an accelerator radiation field is helpful to machine study and operation. For a synchrotron radiation storage ring, shower electrons give a distinct clue to loss location and a BLM-XS model detector is suitable to detect them. Recently, we set up a new beam loss monitoring system by this method for National Synchrotron Radiation Laboratory (NSRL) storage ring. It does not interfere with the vacuum chamber and machine operation. Different from other systems, the detectors are used in pairs, fixed on opposite sides of the chamber separately. Some interesting phenomena about beam lifetime were observed. We located exactly where an excessive beam loss took place during ramping process and solved the problem. It was proved that gas accumulated at the front ends of photo-beam lines strongly impacted the electron beam and led to beam lifetime decreases. The cause of beam lifetime decrease because of superconducting wiggler is discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have