Abstract

The problem of simultaneously exposing large numbers of culture flasks at nominally equivalent incident power densities and with good thermal control is considered, and the radial transmission line (RTL) is proposed as a solution. The electromagnetic design of this structure is discussed, and an extensively bench-tested realization is described. Referred to 1 W of net forward power, the following specific absorption rate (SAR) data were obtained: at 835.62 MHz, 16.0+/-2.5 mW/kg (mean+/-SD) with range (11-22); at 2450 MHz, 245+/-50 mW/kg with range (130-323). Radio-frequency interference from an RTL driven at roughly 100 W is so low as to be compatible with a cellular base station only 500 m distant. To avoid potential confounding by temperature differences among as many as 144 T-75 flasks distributed over 9 RTLs (six irradiates and three shams), temperature within all flasks was controlled to 37.0+/-0.3 degrees C. Experience with over two years of trouble-free operation suggests that the RTL offers a robust, logistically friendly, and environmentally satisfactory solution to the problem of large-scale in vitro experiments in bioelectromagnetics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.