Abstract

The aims of this study in relation to distal radius fractures were to determine (1) the floor and ceiling effects for the QuickDASH and PRWE, (2) the floor and ceiling effects when defined to be within the minimal clinically important difference (MCID) of the minimal or maximal scores, (3) the degree to which patients with a floor or ceiling effect felt that their wrist was ‘normal’, and (4) patent factors associated with a floor or ceiling effect.A retrospective cohort study of patients sustaining a distal radius fracture during a single year was undertaken. Outcome measures included the QuickDASH, PRWE, EQ-5D-3L and normal wrist score.There were 526 patients with a mean age of 65yrs and 77% were female. Most patients were managed non-operatively (73%, n=385). The mean follow-up was 4.8yrs. A ceiling effect was observed for both the QuickDASH (22.3%) and PRWE (28.5%). When defined to be within the MCID of the best score, the effect increased to 62.8% for the QuickDASH and 60% for PRWE. Patients that achieved the best functional outcome according to the QuickDASH and PRWE felt their wrist was only 91% and 92% normal, respectively. Sex (p=0.000), age (p=0.000), dominant wrist injury (p=0.006 for QuickDASH and p=0.038 for PRWE), fracture type (p=0.015), and a better health-related quality of life (p=0.000) were independently associated with achieving a ceiling score.The QuickDASH and PRWE demonstrated ceiling effects following a distal radius fracture. Patients achieving ceiling scores did not consider their wrist to be ‘normal’ for them.