Abstract

AbstractAim: Established clinical indices used to measure dental plaque have limitations. The aim of this study was to develop and evaluate a new method of quantitative plaque measurement, with increased sensitivity and reproducibility, using a purpose designed image analysis system.Method: After plaque disclosure, the patient was positioned in a cephalometric head holder mounted in a custom‐built frame with standard lighting and camera position. A 32‐bit Digital Camera grabbed the image of the patient’s teeth, which was analysed using Adobe Photoshop (V5.02, Adobe Systems Ltd, Europe) and Image Pro Plus software (V4.0, Media Cybernetics, USA). Measurements were made on 120 incisors in 15 patients and reproducibility was assessed using Fliess’ Coefficient of Reliability. Sensitivity was assessed by comparison of results of treatment effects from a clinical trial involving 30 patients. Analysis of covariance was used to compare the image analysis system with the Turesky modification of the Quigley and Hein plaque index and the Addy plaque area index.Results: The results were within the ‘Excellent Reliability’ category, for inter‐operator reproducibility and intra‐operator repeatability.Conclusions: This new system provided accurate quantitative measurements of dental plaque and labial tooth surfaces and was shown to have increased sensitivity when compared with the Turesky modification of the Quigley and Hein plaque index and the Addy plaque area index. The stored images can be re‐measured for reliability and comparability between studies.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call