Abstract

A simple, portable, economical low-temperature atmospheric plasma (LTAP) for bactericidal efficacy of Gram-negative bacteria (Pseudomonas aeruginosa) with different carrier gases (argon, helium, and nitrogen) using the quality by design (QbD) approach, design of experiments (DoE), and response surface graphs (RSG) is presented. Box-Behnken design was used as the DoE to narrow down and further optimize the experimental factors of LTAP. Plasma exposure time, input DC voltage, and carrier gas flow rate were varied to examine the bactericidal efficacy using the zone of inhibition (ZOI). A higher bactericidal efficacy was achieved under the optimal bactericidal factors having ZOI of 50.837±2.418 mm2 with the plasma power density of 132 mW/cm3 for LTAP-Ar at 61.19 s, 14.8747 V, and 219.379 sccm than LTAP-He and LTAP-N2 . The LTAP-Ar was further evaluated at different frequencies and probe lengths to achieve a ZOI of 58.237±4.01 mm2 .

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.