Abstract

Objective:Precise and accurate surgical correction of Patella Alta (PA) requires both a diagnosis of the condition and a target for correction. The radiographic ratios widely used for assessing patella height are flawed for a number of reasons. The Patellotrochlear Index (PTI) addresses some of these deficiencies but is done under passive conditions and in Bierdet’s paper was not related to the diagnosis of PFI. We describe a quadriceps active modification of the PTI, the quads active ratio (Q+R) and assess its reliability and accuracy as a test for the diagnosis of PFI due to PA.Methods:One hundred patients undergoing a clinically indicated knee MRI scan were recruited into the study. Participants had an additional sagittal T1 sequence acquired with maximal static quadriceps contraction. Six scans were technically inadequate. The remaining 94 scans were screened for trochlear dysplasia and 16 scans were subsequently discarded so PFI could be assessed solely in terms of PA. There were 9 cases of PFI in the remaining 78 scans. In 56 of these scans a lateral radiograph was also available. The PTI and Q+R were calculated from MRI scans and the Insall Salvati (IS), Modified Insall-Salvati (MIS), Blackburn Peel (BP) and Caton-Deschamp (CD) ratios from lateral radiographs by 3 surgeons at 3 times points. The inter- and intra-rater reliability of the measures were calculated using intra-class correlation coefficient. Receiver operator curves were constructed to determine the ideal cut-off for each MRI based test for the diagnosis of PFI. Sensitivity and specificity of the MRI based tests for PFI was compared to the IS, MIS, BP and CD ratios using their previously published cut-offs.Results:A main effect of time was found for the PTI (P < 0.01) but not for the Q+R (P = 0.052). A time x surgeon interaction effect was shown for both the PTI and the Q+R (P < 0.01, respectively). However, one-way ANOVA at time point 3 showed no main effect of surgeons for either the PTI (p=0.05) or Q+R (p = 0.09). The Intra-class Correlation Coefficient between surgeons for the PTI and the Q+R ranged from 0.65-0.75 and 0.69-0.83 respectively. The coefficient of variation between surgeons for the PTI and the Q+R ranged from 0.88-9.88% and 2.24-4.85% respectively. According to the area under the receiver operator characteristics curve, the Q+R (AUC, 0.76; SE, 0.06; 95%CI, 0.87-0.64; P < 0.01) was more accurate to detect PFI than the PTI (AUC, 0.74; SE, 0.06; 95%CI, 0.86-0.62; P < 0.05). The Q+R and PTI cut-off scores of 0.12 and 0.36 gave sensitivities of 79.2% and specificities of 55.0% and 50.0% respectively. Of the widely used radiographic indices the Insall-Salvati ratio was the most accurate.Conclusion:The Q+R is more accurate than the PTI for the diagnosis of patella alta causing PFI and addresses many of the deficiencies in other assessment methods. In the absence of trochlear dysplasia a Q+R cut-off of 0.12 may be a reasonable target for correction of Patella Alta.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call