Abstract

Blood samples from 12 normal subjects and 46 patients on oral anticoagulants were divided so that each was anticoagulated with four concentrations of trisodium citrate solution in the range 0.09-0.15 M, 9 vol blood being added to 1 vol citrate solution in each case. Citrated blood haematocrit and plasma prothrombin time was measured on each subsample; 0.025 M CaCl2-solution was used for recalcification throughout. Three laboratories participated, each using a different prothrombin-time technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.