Abstract
The lower hybrid current drive (LHCD) system has been playing an important role in EAST experiments. In recent EAST experiment which lasts 4 months, a 2.45 G 4 MW LHCD system has been successfully applied in the practice. 20 continuous wave klystrons are the core components of the LHCD system. In LHCD, fast protection system and slow protection system are designed to protect klystrons together. Experiments have shown that the multiple protection systems can effectively enhance the safety of klystrons. The paper will describe the two protection systems in details and its components.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.