Abstract

The article presents a comparison of the real overall heat transfer coefficient, based on thermal tests of the condenser of the steam turbine PT-25-90 KTZ during off-design operation (with a degraded vacuum) and its expected value, calculated via the Metropolitan Vickers formula. The average cooling water inlet temperature was 61.2 °C, average exhaust steam pressure was 0.542 bar during thermal tests. The average deviation of the expected overall condenser heat transfer coefficient from the real value was 27,18%. The calculations showed a higher difference between the real and expected value at the regimes with low cooling water velocity and with high exhaust stem pressure. The obtained results showed the need to refine the methodology of the condenser's overall heat transfer coefficient calculation in the degraded vacuum mode. This can be done by adding correction factors to the water temperatures that are typical for the degraded vacuum regime.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.