Abstract

Selenium is a trace element that can be poisonous in small quantities. The aim of this study was to analyze the change in the content of selenium in drinking water, raw water, as well as treated and raw wastewater in an annual cycle in the city of Szczecin. The concentration of Se in samples was determined using the spectrofluorometric method at a 518 nm emission wavelength and a 378 nm excitation wavelength. The amount of selenium in drinking water ranged from <LOD to 0.007 μg/mL, in raw water, from 0.001 to 0.006 μg/mL, in raw wastewater, from 0.001 to 0.008 μg/mL, and in treated wastewater, from 0.001 to 0.009 μg/mL. The selenium content did not exceed the maximum allowable concentration (MAC), 0.010 μg/mL, in any of the water samples tested.