Abstract

SummaryWe report a large number of raptors electrocuted on recently erected electricity distribution lines in the open landscapes of the Mongolian steppe and Qinghai-Tibetan plateau, China. Upland BuzzardsButeo hemilasiusand Saker FalconsFalco cherrug, characteristic raptors of these bioregions, were among those found to be electrocuted. Raptor electrocution was a consequence of poorly designed hardware configurations on anchor poles along surveyed lines on the Qinghai-Tibetan Plateau and, additionally, on line poles in the Mongolian steppe. The design flaws were upright pin-insulators on earthed crossarms and the use of jump wires that passed over crossarms via pin insulators on anchor poles. Targeted mitigation of anchor poles could significantly reduce the incidence of electrocution on the lines surveyed on the Qinghai-Tibetan Plateau, whilst all poles on the lines surveyed in the Mongolian steppe require remediation to make them safe for raptors. The Mongolian steppe and the Qinghai-Tibetan Plateau are bioregions that hold the largest breeding and wintering populations of the globally threatened Saker Falcon. The existing and growing network of dangerous electricity distribution lines in these regions may potentially impact the Saker Falcon population, thus we suggest that preventative and/or mitigation measures are implemented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.