Abstract

Abstract The biggest problem with sanitary technology in high-rise buildings is the design of foul water stacks in which high negative pressure and overpressure values must not occur. When pressure exceeds maximum values, water from the trap is ejected, sucked out, or left bubbling in the trap. Measurements by other researchers have shown that when traps lose their function, in addition to the spreading of unpleasant odors, there is also the spreading of various viruses from the sewer and drainage systems. The paper deals with the mathematical analysis and simulation of the pressure resistance of different traps under various boundary conditions, considering the quality of the internal environment. The effect of water evaporation on pressure resistance was also simulated and assessed. The results of the work are clear tables of pressure resistances with a description of their effect on the water level in the trap.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.