Abstract
Images of the human retina are routinely used in clinical practice for the diagnosis and management of eye disease. Increased permeability of retinal blood vessels, which is a clinically significant feature, can be visualized with a process known as fluorescein angiography as leakage of fluorescence dye into the surrounding tissues. Analyses of such images can be quantified but significant degradation of images due to uneven illumination or occluded optical pathways is often incurred during image capture. We describe a procedure to restore fluorescein angiographic retinal images so that quantitative computation can be reliably performed. Analysis of the image acquisition system reveals that captured images are composed of two functions, one describing the true underlying image and the other the degradation incurred. These two functions are independent of one another and it is possible to estimate the degradation from an isolated captured image and restore it appropriately. Any leakage of fluorescein dye is then detected by analysing the restored angiographic sequence over time and finding areas of the image that do not have the usual decrease in fluorescence intensity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.