Levodopa (L-DOPA) is promising as chiral stationary phase for open tubular capillary electrochromatography (OT-CEC) enantioseparation owing to its self-polymerization adhesive property and chiral recognition potential. In this work, CuSO4/H2O2 was used as a trigger agent to accelerate the polymerization process of L-DOPA and the poly-levodopa (poly-(L-DOPA)) coated column was successfully prepared for the first time by depositing it on the inner wall of fused silica capillary via the rapid and in-situ approach at room temperature. The performance of the poly-(L-DOPA) coated capillary was validated by the separation of different chiral analytes, including chiral amine drugs, neurotransmitters and amino acids, and the good enantioseparation efficiencies were achieved. For five consecutive runs, the relative standard deviations (RSDs) for the migration time of the analytes for intra-day, inter-day and column-to-column were in the range of 0.19–1.33%, 0.96–4.47%, and 2.21–7.79%, respectively. Additionally, the poly-(L-DOPA) coated capillary column could be successively used over 250 runs without observable change in the separation efficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.