Abstract

The spectrographic analysis of volatile acids in a high-purity form is reviewed and a procedure presented that involves evaporation of a 100-g sample under temperature controlled contamination-free conditions and emission spectrography using dc-arc excitation under controlled atmosphere. In the evaporation, graphite (10 mg) is added as a collector, sulfuric acid to convert to less volatile sulfates (with acetic, hydrochloric, and nitric acids), and also mannitol to retain boron (with hydrochloric and hydrofluoric acids). Indium is added as a internal standard. Spectra are examined for 33 elements against a multielement standard in graphite containing indium as an internal standard. For the concurrent analysis of three samples, the elapsed time is 4–10 h and the actual working time 3–5 h. Recovery studies are reported as well as the use of the procedure in the assessment of the leaching of borosilicate glass by concentrated mineral acids.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.