Abstract

Ozone production with Dielectric Barrier Discharge (DBD) is a typical example of the applications of low temperature plasma technology. The most critical process is to inject power into the DBD reactor. But because of the characteristic of DBD reactor, the voltage and current of power supply are distorted severely and make the measurement of input power for DBD ozone reactor even hard. This paper, based on Quasi-synchronous sampling algorithm, establishes the input power measurement systems of DBD ozone reactor and achieves the online real-time monitoring input power of DBD ozone reactor. The experimental results prove that the relative errors of more than 95% is less than0.3% between power measurement system based on Quasi-synchronous sampling algorithm and the measurement data with oscilloscope.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.