Abstract
The potential of Real Time Control (RTC) to reduce the overflow volume from a combined sewer system has been investigated for a catchment in Copenhagen, named Strandvaenget. The results have been compared with the alternative of increasing the storage volume of the system. The RTC strategy has been derived using a mathematical optimization and a rule based method. As the only objective is to reduce the Combined Sewer Overflow (CSO), the developed rule based control algorithm can achieve almost the same results as the optimization method. From the results of time series calculations, it can be concluded that the introduction of RTC appears very promising when the mean yearly CSO volume has to be reduced. In this research, the potential of RTC is investigated for an increasing amount of storage volume and for an increasing demand for reduction of CSO volume.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.