Abstract

The question of what constitutes the “physiologic” behavior of the cupula has been the subject of debate for some time. Calculations are presented which suggest that the cupula constitutes a biological pressure transducer with a threshold of the same order of magnitude as that of the auditory system. This indicates that it would probably be extremely easy to traumatize the cupula by exposing it to pressure gradients far beyond its normal dynamic range in the course of experimental preparations intended to visualize cupula motion. An estimate of the dynamic range of cupula motion may also be obtained which indicates that the center of the cupula may move as little as ten millimicrons at the 0.1 deg/sec2 acceleration levels commonly associated with behavioral thresholds. Accelerations of 30 deg/sec2 or sudden velocity changes of 600 deg/sec, typical of maximal self-induced head motions should produce cupula midpoint motions no greater than about three microns. Because of the small dynamic range of cupula mo...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.