Abstract
Fast neutron radiography is a promising application for accelerator based neutron sources. The potential effectiveness of this technique depends on the development of suitable imaging detectors for fast neutrons. Zinc sulphide based scintillators have the largest light output per event in the family of imaging scintillators used so far in fast neutron radiography. This paper investigated different aspects of this scintillator in order to determine the factors which might affect the light output. A mathematical model was established to estimate effectiveness of this scintillator. Zinc sulphide screens were prepared with ZnS particles of different concentrations in polypropylene matrix. A 14MeV fast neutron source was used in the experiments. The light output was detected using a CCD camera or a film coupled to the scintillator screen. The results showed that the optimum scintillators is around 3mm in thickness with the weight ratio of 2:1 for ZnS and polypropylene.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.