Using passive headspace concentration (ASTM E-1412) and gas chromatographic/mass spectrometric (GC/MS) analysis as described in ASTM E-1618, the authors have studied the volatile components detectable in several kinds of otherwise uncontaminated substrata, including clothing, shoes, household products, building materials, paper products, cardboard, and adhesives. Due to the use of petroleum-derived liquids in the manufacture of these materials, it is frequently possible to detect the liquids, even when the products are several years old. These results point out the need for the use of comparison samples whenever possible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.