Abstract

This paper illustrates a structure of electric floor heating system with latent heat thermal storage plate. This system can charge heat by using cheap nighttime electricity and discharge the heat stored at daytime. A theoretical model is developed, which can analyze the thermal performance of buildings applying such system in winter. The thermal performance of the heating system and the effects of various factors on it are analyzed by modeling and simulation. For a given room located in different climate regions, the optimal effect of using such system is predicted, which testifies the feasibility of this heating mode in different climate regions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.