Abstract
The results of an experimental investigation concerning the operating characteristics of two similar butterfly valves mounted in series are reported. Emphasis is given to the influence of the upstream valve disk angle, the downstream valve disk angle, the relative valve orientation, and the spacing between the valves. The dimensionless pressure drop, the mass flowrate coefficient, and the aerodynamic torque coefficient of each valve are used to characterize the system performance. The results show that the operating characteristics are strongly tied to the combined effect of the two valve disk angles. With noted exceptions, the valve disk orientation and spacing are secondary influences.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.