Abstract

This research was conducted to determine the performance of Reverse Osmosis (RO) membranes in producing pure water, pure water known as mineral-free water or water with zero dissolved solids (TDS = 0 ppm).PDAM (Regional Drinking Water Company) Tirta Musi in Palembang, South Sumatra and water from the Micro Filtration (MF) and Ultrafiltration (UF) processes are fed to the RO process using two feeding methods, namely a single pass and a circulation feed. In a single pass feed, the operating pressure is set at 20 - 50 Psig, where an increase in the product rate and the rejection rate so that the flux increases. Rejection of TDS obtained increased from 96.6% - 97.5%. Furthermore, the circulating feed system with a constant pressure of 50 Psig decreases TDS and Conductivity. Rejection of TDS 96.1% for PDAM water feed and Rejection of TDS for feed water from MF&UF 97.3% in subsequent feedings there was a decrease in TDS and conductivity but not significantly. The purified water produced has a TDS content of 0.16 - 0.48 ppm, a conductivity of 0.17 - 0.49 μs/cm, a pH of 6.99 - 7.2 and a resistivity of 177 - 185 kΩ, the characteristics of this pure water are according to the standard pure water in ASTM D1193 - 99e1 and NCCLS.