Abstract

Perfusion-weighted MRI-based maps of cerebral blood flow (CBF(MRI)) are considered a good MRI measure of penumbral flow in acute ischemic stroke but are seldom used in clinical routine due to methodical issues. We validated CBF(MRI) on quantitative CBF measurement by 15O-water positron emission tomography (CBF(PET)). Comparative CBF(MRI) and CBF(PET) were performed in patients with acute and subacute stroke. In a voxel-based seed-growing technique, predefined CBF(MRI) thresholds (<40, <30, <20, <10 mL/100 g/min) were applied and the resulting volumes were compared with the hypoperfusion volume detected by the penumbral threshold (<20 mL/100 g/min) on CBF(PET). The volumetric comparison was expressed as the C-ratio (volume CBF(MRI)/volume CBF(PET)) to identify the best MRI threshold. The influence of vessel pathology, hypoperfusion size, and time point of imaging was described. The proportion of voxels correctly classified as hypoperfused and the proportion of voxel correctly classified as nonhypoperfused of the best CBF(MRI) threshold was calculated and a Bland-Altman plot illustrated the method-specific differences. In 24 patients (median time MRI to PET: 68 minutes; 16 patients imaged within 24 hours after stroke), the median volume of hypoperfusion <20 mL/100 g/min (CBF(PET)) was 78.5 cm(3). Median hypoperfusion volume on CBF(MRI) ranged from 245.9 cm(3) (<40 mL/100 g/min) to 35.5 cm(3) (<10 mL/10 g/min). On visual inspection, an excellent qualitative congruence was found. The quantitative congruence was best for the MRI-CBF threshold <20 mL/100 g/min (median C-ratio: 1.0), reaching a proportion of voxels correctly classified as hypoperfused of 76% and a proportion of voxel correctly classified as nonhypoperfused of 96%, but a wide interindividual range (C-ratio 0.3 to 3.5) was found. Ipsilateral vessel pathology, time point of imaging, and size of hypoperfusion did not significantly influence the C-ratio. The Bland-Altman analysis for the volumetric difference of CBF(MRI) and CBF(PET) found a good overall agreement but a large SD. Hypoperfusion areas below the CBF(PET) penumbral threshold can be well identified by the CBF(MRI) threshold <20 mL/10 g/min at a group level, but a large individual variance (exceeding 20% of volume in nearly half of the patients) could not be explained. Our results support a prudent use of MRI-based quantitative CBF measurement in clinical routine.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.