Abstract

The output current of grid-connected PV inverters should not excess harmonic contents. Also, because they are driven connected with grid, the reliability of electric power’s quality should be secured. But, the current controllers of the grid-connected PV inverter decrease the electric power’s quality due to not considering the harmonic contents of the output current. This paper proposed the current controllers of the grid-connected PV inverters to supplement the decrease of the electric power’s quality because of the harmonic contents of the electric power’s quality and the harmonic contents of the output current. The proposed current controllers controlled the harmonic contents of the output current by controlling gains of the current controllers in consideration of the harmonic contents of the output current. As a result, when total harmonic distributions of the grid voltage were 0.4% and 4.1%, the excellence of the proposed current controllers was shown through the experience, by obtaining excellent results of being controlled low as the total harmonic distributions of the output current were 0.756% and 0.78% respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.