Abstract
Surgical treatment of high or complex anal fistulas often renders unsatisfying results. This is the report of the first successful closure of such anal fistula using a special Nitinol clip and applicator, the OTSC® Proctology system (Ovesco AG, Tuebingen, Germany): A 54-year old female patient was suffering from a high transsphincteric anal fistula. After seton drainage of the fistula for ten weeks, the fistula track was debrided using a special fistula brush. After transanal clip release from the applicator, the internal fistula opening was adequately closed by the clip. Eight months after clip closure the fistula had healed and the clip was removed using the OTSC® Proctology Clip Cutter. Fistula closure using the OTSC® Proctology system represents a promising sphincter-preserving minimally invasive procedure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.