Abstract

To achieve new emission standards and enhance the denitrification of the oxidation ditch in the Handan West Sewage Treatment Plant, this research used the ASM Bio-P model based on self-made simulation software to study the optimum operation of the denitrification efficiency. The results indicate that:1) the volume of the aerobic zone was increased and the volume ratio between aerobic and anoxic zones was controlled to approximately 3:1; 2) the concentration of the dissolved oxygen (DO) in the aerobic zone was increased and was controlled at 1 mg/L in summer and 3 mg/L in winter; 3) the proper sludge retention time (SRT) was controlled and was maintained at 15 d in summer and 20 d in winter; and 4) the appropriate reflux ratio was controlled to 100% and 50% for summer and winter, respectively. The COD, TN, NH3-N and TP in the effluent reached the first (B) standard of the Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB18918-2002).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.