Abstract

This study develops a high precision non destructive measurement technique based on a laser interferometer for determining the mixture of methanol and ethanol from its refractive index. The optical metrology system is employed to measure the refractive indexes of mixture sample with known methanol and ethanol. The ratio set of the mixture sample have seven sets. The refractive index of the ethanol solution with the methanol alcohol is reduced. When the mixture solution includes the methanol and ethanol, the refractive index of the mixture solution is between the refractive index of the ethanol and methanol. When the refractive index of the solution is very close the refractive index of the ethanol alcohol, the effect of the mixture solution in refractive index is very small. From this experimental result, the effect of the refractive index of the mixture solution in the refractive index of the ingredient liquid is very clear.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.