Abstract

An optical collection system composed of a collection lens, fibers, and a mounting rack with high luminous flux, high transmission efficiency, and low optical losses has been designed and installed to collect sufficient scattered lights for the edge TV Thomson scattering diagnostic on the EAST tokamak. A collection lens with an on-axis optical structure, aspheric lens, and regular shaped image plane is designed to meet the system requirements in terms of field of view, spectral range, aberration, and assembly. A mounting rack is designed to fix the collection system. Fiber back-illumination and a location system are used to install the system to the designed position, and the measurement positions of each fiber are measured by using a portable laser tracker system. This optimized design of the optical collection system can facilitate the establishment of the edge TV Thomson scattering system on EAST, which verifies the feasibility of TV Thomson scattering used in large-scale fusion devices.

Highlights

  • Thomson scattering (TS) diagnostic has been widely applied to measure the fundamental plasma parameters of electron temperature and density profiles for fusion research.1–3 A new edge TV Thomson scattering (TVTS) diagnostic with a high spectral and spatial resolution has been constructed on the EAST tokamak for the study of the pedestal region

  • An optical collection system composed of a collection lens, fibers, and a mounting rack with high luminous flux, high transmission efficiency, and low optical losses has been designed and installed to collect sufficient scattered lights for the edge TV Thomson scattering diagnostic on the EAST tokamak

  • This optimized design of the optical collection system can facilitate the establishment of the edge TV Thomson scattering system on EAST, which verifies the feasibility of TV Thomson scattering used in large-scale fusion devices

Read more

Summary

INTRODUCTION

Thomson scattering (TS) diagnostic has been widely applied to measure the fundamental plasma parameters of electron temperature and density profiles for fusion research. A new edge TV Thomson scattering (TVTS) diagnostic with a high spectral and spatial resolution has been constructed on the EAST tokamak for the study of the pedestal region. Thomson scattering (TS) diagnostic has been widely applied to measure the fundamental plasma parameters of electron temperature and density profiles for fusion research.. A new edge TV Thomson scattering (TVTS) diagnostic with a high spectral and spatial resolution has been constructed on the EAST tokamak for the study of the pedestal region. Since the electron temperature and density are calculated from the shape and intensity of the scattering spectrum, respectively, the performance of the optical collection system can directly affect the measurement accuracy and range of the TVTS diagnostic.

DESIGN PARAMETERS
Design of the collection lens
Design of the mounting rack
CONCLUSIONS

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.