Abstract

The novel staggered flow alternation structure (SFAS) proposed in prior study has proved to be an efficient way in improving the overall thermal performance with acceptable pressure drop penalty in Double-layer Microchannel Heat Sinks (DMHSs). Based on the prior design, a further numerical investigation concerning the optimum location of SFAS in DMHSs is presented. The corresponding temperature fields, Nusselt number, flow fields, pressure drop and thermal characteristics are presented through verified computational mode. In addition, the effect of flow arrangements such as concurrent, upper-inlet/lower-inlet countercurrent arrangement on the thermal performance are studied in more details. The best thermal location of SFAS in the DMHSs is found to be based on the alterable locations and multi-flow directions. Yet, changing the location of staggered alternation structure does not lead to an appreciable rise of pressure drop penalty in DMHSs. However, the improvement in thermal performance for upper-inlet countercurrent arrangement is significant. Placing the SFAS in the middle of the DMHSs ensures the best overall thermal performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.