Abstract

The values of the nucleation parameter, k, for bubble nucleation induced by high energy heavy ions 12C (180 MeV/u), 20Ne (400 MeV/u) and 28Si (350 MeV/u) in superheated emulsion detector are determined by comparing the experimentally obtained normalized count rates with those obtained from simulations done using the GEANT3.21 simulation code.The results show that the nucleation parameter depends on the mass number of the incident heavy ions, and decreases with increasing mass number.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.