Abstract
In this research, we proposed nondestructive evaluation method of a flaw in an optical glass lens by resonant ultrasound spectroscopy (RUS). An optical glass lens is used for improving signal coupling between fibers, emitters and detectors. The shape of optical glass lens is an aspherical lens with 3mm in length and 6.35 mm in diameter. For nondestructive evaluation of an aspherical lens, we made of the measuring system by RUS. For flaw evaluation by the RUS to verify the data obtained from the experiment, we carried out simulation by explicit finite elements method, and compared the experimental results with simulation results. Also, we compared the resonant frequencies of specimens with some defect with those of acceptable specimens. The histogram drawn from these data and the available resonance mode surveyed were used to classify the acceptable specimens in the plant.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.