Abstract
We have developed a novel apparatus for applying a nitrogen boil-off method as a mean of making calorimetric measurements and allowing for simple measuring and evaluating of AC losses in HTS coils at liquid nitrogen temperature. With the ability to measure AC loss generated in superconductors directly, this method produces more reliable data than that obtained by general, electro-magnetic measurements. A sensitivity of about 0.1 W was achieved by improving sensitivity in measuring gas evaporation via the following three steps: (1) use of nonmetallic vessel, heat-insulated housing in which the sample is located; (2) optimization for sample vessel thickness and tube size; and (3) stabilization of evaporating gas emitted by the heater. It is widely expected that the proposed apparatus may be used for individual measurement of the magnetization loss and the transport current loss in HTS coils, as well as their total losses, in addition to the AC loss in irregularly shaped samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: IEEE Transactions on Applied Superconductivity
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.