The contribution presents the new non-destructive diagnostic methods for the insulating material diagnostics of electrical rotary machine windings. The theory of the diagnostic methods is presented, and these methods are verified in laboratory conditions on Relanex insulating material. This material is used for insulation of electrical rotary machine windings. Attention is focused on determining the breakdown voltage correlation with diagnostic quantities. The relationship between breakdown voltage and the diagnostic quantities is also assessed by a non-traditional method, i.e., by a cluster analysis. More methods of the cluster analysis were used, and all results obtained were analysed and justified.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.