Abstract
Neutral transport related to recycling phenomena on two limiters installed in the central-cell was studied in the GAMMA 10 tandem mirror plasmas. Dependence of iris limiter is investigated in terms of plasma diamagnetism and Hα-line intensity. It was found that a plasma diamagnetic signal was improved and Hα-line intensity near the iris limiter increased if the diameter of the iris limiter shrank to 340 mm. Fully 3-dimensional MonteCarlo simulation (DEGAS) was executed with the recycling source on the limiters. The neutral sources on the limiters were consistently given so as to satisfy 2-di mensional (2-d) image obtained by a high-speed camera. The determined Hα-line intensity from DEGAS well explained the experimental result. The simulation result, in the 340 mm case, predicted the reduction in the peak value of Hα-line intensity on the central limiter and the enhancement on the iris limiter. It suggests that the reduction of the recycling on the central limiter makes it possible to lead the better plasma performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.