Abstract

The neutron-induced positron source NEPOMUC at the FRM II provides a mono-energetic positron beam of high intensity of the order of 109 moderated positrons per second. The new layout of NEPOMUC upgrade is presented and the constraints for operating an in-pile positron source at a research reactor are discussed. Inside the tip of the new beam tube, 80% 113Cd-enriched Cd is used as a neutron-γ-converter that has a projected lifetime of 25 years of reactor operation and thus ensures positron beam experiments in the long term. The source consists of Pt foils that both generate positrons, by pair production, and moderate them. The layout of these foils, the electric lenses and the magnetic fields for positron extraction and beam formation have been improved. In addition to a higher beam intensity, it is expected that the beam brightness will improve by at least one order of magnitude. The present and planned experiments range from fundamental studies in nuclear, atomic and plasma physics to high-sensitivity and element-selective investigations in surface and solid state physics to applications in materials science. The upgrade of several positron spectrometers as well as new positron beam experiments are presented. In addition, a new switching and remoderation unit will allow us to toggle from the high-intensity primary beam to a brightness enhanced remoderated positron beam.