Abstract

The problem of soil–structure interaction analysis with the direct method is studied. The direct method consists of explicitly modeling the surrounding soil to bedrock and the structure resting on the soil. For the soil medium, usually the traditional equivalent linear method with a reduced shear modulus and an increased damping ratio for the soil is used. However, this method does not work in the vicinity of foundation where the soil behavior is highly nonlinear because of presence of large strains. This research proposes a modified equivalent linear method with a further reduction of the soil shear modulus in the near-field of foundation that results in validity of using the equivalent linear method throughout. For regular short, intermediate and tall structures resting on such soft soils, a series of dynamic time-history analysis is implemented using earthquake records scaled to a sample design spectrum and the nonlinear structural responses are compared for different assumptions of soil behavior including the elasto-plastic Mohr–Coulomb, the traditional equivalent linear, and the proposed modified equivalent linear method. This analysis validates the proposed method.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call