Abstract
The monitored performance of the first new London dwelling certified to the Passive House standard is presented. The first detailed analysis of the energy consumption of the heating, ventilation and domestic hot water systems are given. The annual space heating demand of the 2 bedroom, 101m2 dwelling was 12.1kWh/m2, achieving the 15kWh/m2 Passive House target. The annual primary energy demand was 125kWh/m2, marginally above the 120kWh/m2 target. The measured internal heat gains of 3.65W/m2 are much greater than the 2.1W/m2 suggested as standard for dwellings. The Passive House Planning Package, PHPP, is found to be a good predictor of space heating demand and the risk of summer time over heating. Winter space heating demand is sensitive to occupant blind use. With a total metered energy consumption of 65kWh/m2, the Camden Passive House is one of the lowest energy, small family dwellings, monitored in the UK.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.