Abstract

We describe an improved piston corer, the Mk II, for sampling soft sediments for ancient DNA analysis. The original Mk I model, designed to minimize contamination and successfully used in New Zealand, was subsequently deployed on Easter Island where three problems arose. Two of these problems related to sediment and water entering the core barrel and contaminating samples. The other difficulty was that plant material accumulated ahead of the piston and blocked the corer aperture. Design improvements were made to the prototype model and eliminated these problems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.