In this paper the architecture of the MHD control system for the Frascati Tokamak Upgrade (FTU) is presented. A set of hardware consisting of FPGA and DSP modules on PXI bus for executing the control and estimation algorithms is proposed. Data communication among the hardware modules in both on-line experiment mode and off-line data acquisition has been described. A model predictive protection system has been developed to monitor the antenna angles in real-time to predict the rest position of the antennas based on the mechanical model of the antennas mechanical and motor drive system in order to prevent any mechanical damage by alarming the control system and stopping the motors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.