Abstract

Abstract Variable-speed pumped storage technology was being increasingly adopted by new power system to improve the operating and regulating characteristics of the hydropower unit and to stabilize the grid fluctuations. By connecting to a frequency converter, the variable-speed pumped storage unit can respond to grid fluctuations at a speed of hundreds of milliseconds. The fast response capability of a variable-speed pumped storage turbine should be considered in the design stage, be identified during the model test and be used as prerequisite during the commissioning stage of the unit. This article described the method for identifying the fast response capability and methods for improving the power regulation potential of a variable-speed pumped turbine in pump mode. The pipeline hydraulic loss, the guide vanes opening, the energy, cavitation and hump characteristics of the pump are the key parameters and should be carefully considered during the selection of the variable-speed operating zone.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.