Abstract
AbstractTemperature profiles of dispersed kerosene and water were measured in a spray column heat exchanger, 15 cm. in diameter and 160 cm. long. Dispersed packing of drops and narrow temperature ranges were used. The flow rates used were 0 to 50 liters/min. of water and 5 to 40 liters/min. of kerosene. The physical picture that emerges from the temperature profiles is that heat is transferred from fully mixed drops to fully mixed wakes while the wakes are formed, by shedding and renewal of elements of wakes in most of the column and by complete mixing of all streams at the water inlet at the top of the column. Mathematical equations were developed from the physical model. The volume of the wakes and the rate of shedding of wake elements were estimated from the temperature profiles and were used to calculate the temperature profiles for this and for other studies. The agreement of the calculated profiles with the experimental data is very good.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: AIChE Journal
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.