Abstract
Reports of the anomeric composition of amorphous lactose are rare and state a highly variable range of composition (between 0% and 60% w/w β content). We aimed to develop a quantitative measurement by (1)H-NMR of α and β anomer content in amorphous lactose produced by different production methods. Amorphous lactose was prepared by spray and freeze drying 10% w/v aqueous solutions of lactose. NMR analysis was performed in DMSO; peak areas of partially resolved doublets at 6.3 and 6.6ppm were used to calculate % of α and β lactose present. Polarimetery was used to determine optical rotation of lactose solutions. Observed specific rotation for supplied crystalline alpha lactose monohydrate of 88° recorded in DMSO was constant for the length of a typical NMR experiment (max. 10min). β/α anomer contents of amorphous lactose measured by (1)H-NMR had standard deviations as low as 0.1% w/w (n = 6). Drying a lactose solution 4h after its preparation led to almost 35% w/w difference in anomer composition within solid amorphous material compared to samples dried after only 30min, e.g. for freeze dried samples, β content was 60 ± 0.1% w/w (4h) and 25 ± 1.0% w/w (30min). Mutarotation leads to this increase in β anomer concentration in aqueous solution and within the solid amorphous lactose stored at 25°C. e.g. after 56 d storage the β content of freeze dried lactose (30 min solution) increased from 25±1.0% to 50±0.5% w/w. A simple solution-based (1)H-NMR method for measurement of anomeric composition of lactose has been established. The solution β/α ratio at the time of drying is mirrored in the composition of the resulting solid amorphous material. In order to produce a consistent anomer composition within spray and freeze dried amorphous lactose, the standing time for the feed solution should be greater than 4 h, such that the most dynamic region of the mutarotation profile has been exceeded. If the amorphous material has been formed from a solution that has not been allowed to equilibrate for 4 h, the resulting solid will continue to undergo mutarotation if trace amounts of moisture are present, until the anomeric β/α ratio slowly approaches 1.7.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.