Abstract
To provide adequate protection on tunnel structure in the case of a fire, the maximum smoke temperature exposure to the construction under tunnel ceiling should be estimated. Theoretical analysis of smoke temperature under the ceiling based on the plume theory is given. The heat release rate and longitudinal ventilation velocity are both taken into account. And small-scale experimental tests were also carried out to investigate the maximum temperature under the ceiling in tunnel fires. Results of analysis and experiments both show that the maximum temperature rise under the ceiling can be divided into two regions- when the dimensionless parameter u/w* is larger than 0.12 the maximum temperature under tunnel ceiling linearly increases with the heat release rate and linearly decreases with the longitudinal ventilation velocity. And when the dimensionless parameter u/w* is smaller than 0.12, and the maximum temperature under the ceiling varies as two-third power of the dimensionless heat release rate, independent of the longitudinal ventilation velocity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.