Abstract

A new 100 cm long 16.5 French valvuloplasty introducer was used in 12 consecutive patients (mean age 73 years, five males and seven females) undergoing aortic balloon valvuloplasty for severe aortic stenosis. The long‐sheath was introduced into the ascending aorta along the stiff part of an exchange guidewire. The valvuloplasty procedure, which included a complete diagnostic catheterization in three patients, lasted 113 ± 47 min (211 ± 81 min in the previous 18 procedures performed with a conventional approach, P < 0.05). Introduction of balloon catheters (3 × 12 mm trefoil balloon in the 12 cases and 2 × 19 mm bifoil balloon in 2 of these cases) was possible in all patients and an increased stability of the balloon during inflation was observed. No systemic embolization or vascular complications occurred at the puncture site. The long‐sheath technique appears to be a valuable adjunct for aortic valvuloplasty in that it provides easier and quicker access for even the largest balloons and additional support and stability during balloon inflation. In our experience, this reduced the practical difficulties and the duration of the procedure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.