The electromagnetic shower detection system of the Mark II Magnetic Detector consists of ten large lead/liquid argon modules. Eight of these, termed "barrel" modules, are placed outside the aluminum coil which defines the magnetic field volume of the device. The other two, the "end-cap" modules are placed at the ends of the solenoid. The design and construction of the lead assemblies, the tank structure and the cryogenic system will be described, as will the data acquisition electronics. Preliminary results on the performance of the first barrel module will be presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.