Abstract

The L3 vertex detector is comprised of the time expansion chamber (TEC), the Z-chamber and a layer of plastic scintillating fibers. The TEC has shown a high spatial resolution and an excellent multi-track reconstruction capability at LEP luminosity. The Z-chamber provides information about the z-coordinates of the tracks and the fibers are used for calibrating the drift velocity with a high precision. A description of the L3 vertex detector, its readout and data acquisition and its performance during the 1990 LEP running period is presented in this paper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.