Abstract

Heavy ion radiation experiments have been done to DC/DC converters with different topological structures for space applications. The test results were analyzed about the function failure of three topological structures caused by single event effects. The relationship between the function failure and the input supply voltage, the output load current and the topological structure of the module were discussed. Based on the analysis of the variation relationship among the source/drain terminal voltage of MOSFETs and the input voltage and the output load, the sensitivity factors associated with the function failure caused by single event effects were discussed. A new analysis on single event function failure of DC/DC converter based on different topologies has been presented, which can be applied to radiation hardened design and space application.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.