Abstract
A high-accuracy fast-acting simple in implementation and invariant to interferences in the form of direct current signal method of non-coherent harmonic alternating current signals vectors sets measurement is described. The solution of stated in the general view problem is gained on the base of so called the splitting sets of samples method and invariant theory approach to measurement process organization. The implementation of the method is illustrated on example of a synthesis of the measurement algorithm for the case of three harmonic signals. The analysis of the gained results is given.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.