Abstract

An RF survey meter is often used to evaluate the safety of human exposure to RF electromagnetic fields. However, it has been noted that erroneous meter indications occur when the meters are used in strong, extremely low-frequency (ELF) electric fields, such as those found near electric power transmission and distribution facilities. In this paper, coupling between an ELF electromagnetic field and an RF survey meter has been studied theoretically and experimentally. It has been shown that coupling large enough to result in erroneous readings can be caused by unbalanced currents as small as 0.1% of the balanced currents on the transmission line that connects the probe to the readout unit. Unbalanced currents of this magnitude can be caused by capacitive coupling to the probe and readout unit.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.